Engineering · Dearborn, MI

Hybrid Full-time

Cell DV/PV Testing Engineer, Ford Energy

Ford · Dearborn, MI · Posted Oct 26, 2026

This posting comes from Ford. Confirm the details on their site before applying.

Overview

Ford Energy is a newly formed, wholly-owned subsidiary of Ford Motor Company dedicated to accelerating U.S. energy independence. Leveraging Ford’s century of manufacturing excellence and world-class battery energy storage systems (BESS) technology, Ford Energy designs, manufactures, and services grid-scale and commercial DC battery energy storage systems (BESS).

Responsibilities

  • Core Responsibilities
  • Cell Performance & Life Testing (Internal)
  • Execute DV and PV test plans (DVP&R/PVP&R) on internally sourced battery cells, with primary emphasis on performance and life characterization: capacity, impedance/DCIR, rate and power performance, cycle life, calendar life, and coulombic efficiency testing.
  • Set up and operate cell test equipment, including battery cyclers, environmental and thermal chambers, and data acquisition systems, to generate performance and life data.
  • Support supplementary environmental testing (e.g., thermal cycling, vibration, shock) as needed to complete DV/PV requirements, in coordination with test labs or other engineering teams.
  • Supplier Test Tracking & Analysis
  • Track the status and schedule of cell test programs being executed by external suppliers, ensuring test plans align with internal DV/PV requirements and program timelines.
  • Collect and analyze supplier-generated performance and life test results; compare against internal requirements, internally generated data, and prior supplier lots to identify gaps, trends, or discrepancies.
  • Coordinate with supplier engineering contacts to clarify test methods, request missing data, and follow up on open issues or anomalies identified in supplier test results.
  • Support review of supplier quality documentation (e.g., DFMEA/PFMEA, control plans, PPAP) as it relates to cell performance and life test data.
  • Summarize supplier test outcomes for cell design, quality, and program teams, and flag risks that may affect supplier qualification or sourcing decisions.
  • Failure Diagnostics & Teardown Analysis
  • Diagnose cell-level failures and anomalies identified during DV/PV testing, field returns, or production builds, applying structured root-cause analysis methods (e.g., 8D, fishbone/Ishikawa, 5-Why).
  • Plan and perform teardown analysis of failed or suspect cells, including mechanical disassembly, visual and optical inspection, electrical characterization, and coordination with materials science/failure-analysis labs (e.g., SEM, XRD, CT scan) as needed.
  • Document teardown findings, failure modes, and probable root causes in clear, traceable reports; recommend and track corrective and preventive actions.

Requirements

  • Bachelor's degree in Electrical, Chemical, Mechanical, Materials, or a related engineering discipline.
  • 3+ years of experience testing battery cells or battery systems in a lab or validation environment.
  • Hands-on experience setting up and operating battery cyclers, environmental/thermal chambers, and data acquisition systems.
  • Working knowledge of DV/PV testing methodology and DVP&R/PVP&R documentation, with a strong grounding in cell performance and life test methods.
  • Experience or working knowledge of failure analysis and teardown techniques for battery cells (mechanical disassembly, visual/optical inspection, electrical characterization).
  • Experience tracking or analyzing test results generated by external suppliers or test labs.
  • Ability to read and interpret test specifications, engineering drawings, and cell datasheets.
  • Strong data analysis skills (Excel and/or MATLAB/Python) and clear technical report writing.
  • Ability and willingness to work in a lab environment with battery test articles, including required PPE and safety protocols.
  • Ability and willingness to travel occasionally to supplier or external test lab sites.
  • Master's degree in Electrical, Chemical, or Materials Engineering.
  • Experience with LFP (lithium iron phosphate) or sodium-ion cell chemistries and their characteristic performance and life behavior.
  • Experience performing cell teardown and failure analysis, including use of techniques such as SEM, XRD, CT scanning, or similar diagnostic tools (directly or via coordination with a materials/failure-analysis lab).
  • Experience supporting production teams during process validation (PV) builds, including real-time troubleshooting and non-conformance resolution.
  • Exposure to evaluating or developing next-generation/alternative cell chemistries for energy storage applications.

Benefits

  • Health insurance, Dental insurance, Vision insurance, Paid time off, Parental leave, Tuition reimbursement, Bonus, Childcare assistance

Great fits start here.

Whether you're looking for your next role or your next team member, give people and possibilities a place to meet.