Engineering · Kenilworth, NJ

Facilities Command Center Engineer (night position)

CoreWeave · Kenilworth, NJ · Posted Sep 4, 2026

This posting comes from CoreWeave. Confirm the details on their site before applying.

Overview

The Global Data Center Operations team serves as the backbone of our infrastructure, ensuring the seamless performance of our global hyperscale environment. Operating in a high-stakes, 24/7 setting, this team is responsible for safeguarding the availability, stability, and reliability of mission-critical systems that power our most essential services. As a Facilities Command Center Engineer, you bring facilities engineering judgment to mission control for our global data center fleet.

Responsibilities

  • Make the call when no runbook fits: assess risk to production, decide whether to dispatch, and direct the first response within defined limits.
  • Review work requests, MOPs, and change records submitted by site teams and vendors for safety and operational compliance before work is authorized.
  • Conduct scheduled remote rounds each shift, reviewing and recording the health of electrical, mechanical, and fire/life safety systems across the fleet.
  • Monitor critical assets including UPS systems, standby generators and fuel systems, switchgear, PDUs, battery plant, chillers, CRAH/CRAC units, cooling towers, pumps, air handlers, and fire suppression systems.
  • Baseline normal operating conditions, trend performance across sites, and identify drift and early-warning signatures before they become events.
  • Serve as first responder for infrastructure alarms, triaging incidents and initiating response per SOPs, MOPs, and EOPs.
  • Escalate to on-site operations, engineering teams, and leadership based on defined escalation matrices, with a clear technical assessment attached.
  • Coordinate incident response across multiple teams and sites, and remotely support on-site technicians, vendors, and contractors during events and planned maintenance.
  • Write and correct operating procedures based on what you see across the fleet, and feed lessons learned back to site leadership.
  • Act as technical lead on root cause analysis, providing timelines, alarm histories, and an engineering read of what failed and why.
  • Coach Command Center Technicians on your crew and help them build the facilities depth to grow into this role.
  • Maintain detailed event logs and lead structured shift handovers to keep operations continuous across crews.

Requirements

  • 4+ years of experience operating or maintaining critical facilities: data centers, utilities and power generation, hospitals, semiconductor fabs, or industrial plants.
  • Hands-on background in electrical systems (UPS, switchgear, generators, ATS/STS, batteries) or mechanical systems (chillers, CRAH/CRAC, cooling towers, pumps, controls), with working knowledge of the other.
  • Ability to read and reason from one-line diagrams, P&IDs, and sequences of operation.
  • Proven experience writing, reviewing, and executing SOPs, MOPs, and EOPs in high-availability environments.
  • Experience making operational decisions under pressure with incomplete information, and explaining the reasoning afterward.
  • Ability to interpret telemetry, trend data, and alarm behavior to separate real risk from noise.
  • Strong written communication. Much of your work product is the written record of what happened, why, and what to change.
  • Ability and willingness to work 12.5-hour shifts on a fixed two-week rotating pattern, including weekends, holidays, and nights if assigned to a night crew.
  • Work is performed in a climate-controlled Command Center, primarily seated at a multi-monitor operator workstation.

Preferred qualifications

  • Bachelor's degree in Electrical or Mechanical Engineering, or equivalent military technical training (for example, Navy nuclear or marine engineering programs).
  • Experience as a data center facility engineer, critical facilities engineer, or chief engineer in a hyperscale or colocation environment.
  • Stationary engineer, electrical, or HVAC trade license.
  • Data center operations certifications such as CNet CDCTP or Uptime Institute AOS/ATD.
  • Familiarity with specific BMS, EPMS, and DCIM platforms.
  • Experience in a centralized Command Center, Facility Operations Center, or NOC supporting multiple sites.
  • Experience with root cause analysis methods and incident management frameworks.
  • You love to understand how a system really behaves, not just what the alarm says.
  • You're curious about why the same failure keeps showing up at different sites.
  • You're an expert in staying calm and making a sound call during high-severity incidents.

Benefits

  • Medical, dental, and vision insurance - 100% paid for by CoreWeave
  • Company-paid Life Insurance
  • Voluntary supplemental life insurance
  • Short and long-term disability insurance
  • Flexible Spending Account
  • Health Savings Account
  • Tuition Reimbursement
  • Ability to Participate in Employee Stock Purchase Program (ESPP)
  • Mental Wellness Benefits through Spring Health
  • Family-Forming support provided by Carrot
  • Paid Parental Leave
  • Flexible, full-service childcare support with Kinside

Great fits start here.

Whether you're looking for your next role or your next team member, give people and possibilities a place to meet.