Installation and Repair · Remote

Remote Full-time

Site Acceptance Testing Technician

Crusoe · Remote · Posted Nov 14, 2026

This posting comes from Crusoe. Confirm the details on their site before applying.

Overview

The Field Service Technician – Mechanical Integration & Field Site Acceptance plays a vital role in the field deployment, mechanical integration, site acceptance testing (SAT), and field support for Original Equipment Manufacturer (OEM) data center infrastructure. Operating directly within client and enterprise data center sites, the technician ensures high-reliability installation and mechanical validation of Modular Data Centers (MDCs), power distribution skids, high-density GPU/server racks, thermal containment systems, and cooling manifolds.

Responsibilities

  • Perform on-site mechanical positioning, structural anchor mounting, and precision alignment for modular data centers (MDCs), GPU/server rack assemblies, power skids, and containment structures.
  • Rig, position, level, and secure heavy OEM sub-assemblies and fluid distribution manifolds using precision leveling gear, torque tools, and field rigging equipment.
  • Execute field installation of cooling lines, quick-disconnect (QD) fittings, and fluid interconnects following engineering drawings and exact torque specifications.
  • Conduct field structural integrity checks, vibration isolation verifications, and environmental sealing on modular enclosures.
  • Execute Site Acceptance Testing (SAT) protocols for newly landed OEM equipment to verify mechanical integrity and installation readiness prior to final customer handover.
  • Perform mechanical and visual quality inspection checklists during uncrating, landing, and positioning at client facilities.
  • Document SAT outcomes, maintain field test logs, and compile detailed punch-lists for any mechanical or cosmetic anomalies observed on site.
  • Partner with client data center facility teams, general contractors, and commissioning engineers to resolve field integration issues efficiently.
  • Support low-voltage control circuits (24VDC, sensor loops, and signal lines) on OEM equipment as non-licensed field support.
  • Perform basic multi-meter continuity checks and voltage measurements on non-energized control loops and terminal blocks.
  • Execute precise wire stripping, terminal block termination, crimping, wire lacing, and cable management inside OEM control cabinets.
  • Observe strict electrical boundary limits: high-voltage AC connections, main electrical panel wiring, and licensed electrician duties are explicitly out of scope.
  • Serve as the primary technical field representative for OEM equipment landing, mechanical troubleshooting, and field modification kits.
  • Complete daily site logs, field service reports, redline drawing revisions, and material tracking forms accurately.
  • Adhere strictly to environment, health, and safety (EHS) guidelines, Personal Protective Equipment (PPE) rules, and site-specific Lockout/Tagout (LOTO) procedures.

Requirements

  • High school diploma or equivalent; trade school diploma or technical certification in mechanical technology, field service, or industrial maintenance is highly desirable.
  • 2–5+ years of practical field service, mechanical installation, or field integration experience within data centers, critical facilities, industrial power, or HVAC environments.
  • Hands-on proficiency with mechanical hand/power tools, torque wrenches, precision measurement devices, and leveling equipment.
  • Ability to read and interpret mechanical assembly drawings, structural layouts, and field installation procedures.
  • Physical capacity to lift up to 50 lbs unassisted, work in confined spaces inside modular units, and perform work at elevated heights safely.
  • Mobility and willingness to travel to client data center project locations as required.

Preferred qualifications

  • OEM Data Center Equipment: Direct field experience with modular data centers (MDCs), power skids, server/GPU rack containment, and fluid distribution manifolds.
  • Basic Electrical Wiring & Schematics: Familiarity with low-voltage wiring fundamentals, reading control schematics, wire stripping, terminal block wiring, and cable lacing techniques.
  • Low-Voltage Diagnostics: Hands-on experience operating digital multimeters for non-energized continuity verification and low-voltage (24VDC/signal) troubleshooting.
  • Hydraulic & Cooling Systems: Working knowledge of liquid cooling loops, pressure testing procedures, and quick-disconnect manifold connections.
  • Safety Credentials: Active OSHA 10 / OSHA 30 card, NFPA 70E awareness, and signalperson/rigging safety training.

Benefits

  • Competitive compensation and equity packages
  • Restricted Stock Units
  • Paid time off, paid holidays & leave of absence programs
  • Comprehensive health, dental & vision insurance
  • Employer contributions to HSA account
  • Paid parental leave
  • Paid life insurance, short-term and long-term disability
  • Professional development & tuition reimbursement
  • Mental health & wellness support
  • Commuter benefits (parking & transit)
  • Cell phone stipend
  • 401(k) Retirement plan with company match up to 4% of salary

Great fits start here.

Whether you're looking for your next role or your next team member, give people and possibilities a place to meet.