Maintenance Technicians · Remote

Remote Full-time

Field Service Technician – Mechanical Integration & Field Site Acceptance

Crusoe · Remote · Posted Nov 17, 2026

This posting comes from Crusoe. Confirm the details on their site before applying.

Overview

Join Crusoe Energy as a Field Service Technician specializing in Mechanical Integration & Field Site Acceptance. In this vital field role, you will drive the on-site deployment, mechanical integration, site acceptance testing (SAT), and field support for Original Equipment Manufacturer (OEM) data center infrastructure.

Responsibilities

  • Mechanical Integration & Positioning: Perform on-site mechanical positioning, structural anchor mounting, and precision alignment for modular data centers (MDCs), GPU/server rack assemblies, power skids, and containment structures.
  • Rigging & Heavy Sub-Assembly Installation: Rig, position, level, and secure heavy OEM sub-assemblies and fluid distribution manifolds using precision leveling gear, calibrated torque tools, and field rigging equipment.
  • Cooling & Fluid Interconnects: Execute field installation of cooling lines, quick-disconnect (QD) fittings, and fluid interconnects following engineering drawings and exact torque specifications.
  • Structural & Environmental Validation: Conduct field structural integrity checks, vibration isolation verifications, and environmental sealing on modular enclosures.
  • Site Acceptance Testing (SAT): Execute SAT protocols and mechanical/visual quality inspection checklists during uncrating, landing, and positioning to verify mechanical integrity and installation readiness prior to customer handover.
  • Quality Documentation & Punch-Lists: Document SAT outcomes, maintain field test logs, and compile detailed punch-lists for any mechanical or cosmetic anomalies observed on site.
  • Non-Licensed Low-Voltage Control Support: Support low-voltage control circuits (24VDC, sensor loops, and signal lines) on OEM equipment by executing precise wire stripping, terminal block termination, crimping, wire lacing, and cable management inside OEM control cabinets.
  • Low-Voltage Diagnostics & Boundary Compliance: Perform basic digital multimeter continuity checks and voltage measurements on non-energized control loops and terminal blocks while strictly observing electrical boundary limits (excluding all high-voltage AC connections, main electrical panel wiring…
  • Cross-Functional Field Representation: Serve as the primary technical field representative for OEM equipment landing, mechanical troubleshooting, and field modification kits, partnering with client facility teams, general contractors, and commissioning engineers to resolve integration issues.
  • Field Reporting & EHS Compliance: Complete daily site logs, field service reports, redline drawing revisions, and material tracking forms accurately while strictly adhering to Environment, Health, and Safety (EHS) guidelines, Personal Protective Equipment (PPE) rules, and site-specific…

Requirements

  • Education: High school diploma or equivalent.
  • Experience: 2–5+ years of practical field service, mechanical installation, or field integration experience within data centers, critical facilities, industrial power, or HVAC environments.
  • Technical & Tool Proficiency: Hands-on proficiency with mechanical hand and power tools, torque wrenches, precision measurement devices, and leveling equipment.
  • Blueprint & Drawing Interpretation: Ability to read and interpret mechanical assembly drawings, structural layouts, and field installation procedures.
  • Safety & Electrical Boundary Discipline: Commitment to working safely within strict non-licensed low-voltage boundaries and following site-specific LOTO, PPE, and EHS protocols.
  • Physical & Operational Requirements: Physical capacity to lift up to 50 lbs unassisted, work in confined spaces inside modular units, and perform work at elevated heights safely.
  • Travel Readiness: Mobility and willingness to travel to client data center project locations as required.

Preferred qualifications

  • Trade school diploma or technical certification in mechanical technology, field service, or industrial maintenance.
  • Direct field experience with OEM data center equipment, including modular data centers (MDCs), power skids, server/GPU rack containment, and fluid distribution manifolds.
  • Familiarity with low-voltage wiring fundamentals, reading control schematics, wire stripping, terminal block wiring, and cable lacing techniques.
  • Hands-on experience operating digital multimeters for non-energized continuity verification and low-voltage (24VDC/signal) troubleshooting.
  • Working knowledge of liquid cooling loops, pressure testing procedures, and quick-disconnect manifold connections.
  • Active safety credentials, including an OSHA 10 or OSHA 30 card, NFPA 70E awareness, and signal person/rigging safety training.

Benefits

  • Competitive compensation and equity packages
  • Restricted Stock Units
  • Paid time off, paid holidays & leave of absence programs
  • Comprehensive health, dental & vision insurance
  • Employer contributions to HSA account
  • Paid parental leave
  • Paid life insurance, short-term and long-term disability
  • Professional development & tuition reimbursement
  • Mental health & wellness support
  • Commuter benefits (parking & transit)
  • Cell phone stipend
  • 401(k) Retirement plan with company match up to 4% of salary

Great fits start here.

Whether you're looking for your next role or your next team member, give people and possibilities a place to meet.